HA Group Notification (FILESYSTEM DISK FAILED Shelf XX, Bay YY, Model ...) ERROR
Applies to
- All FAS and AFF models
- ONTAP 9
- Data ONTAP operating in 7-Mode
Issue
- AutoSupport reports a failed disk.
HA Group Notification (FILESYSTEM DISK FAILED Shelf 22, Bay 14, Model [X422_HCOBE600A10], S/N [XXXXXXXX]) ERROR
- EMS messages similar to:
Sun Jul 26 08:22:21 CEST [node_name: raidio_thread: raid.disk.predictiveFailure:error]: Disk /aggregate/plex0/rg2/0a.22.14 Shelf 22 Bay 14 [NETAPP X422_HCOBE600A10 NA02] S/N [XXXXXXXX] UID [xxxxxxxx:xxxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] reported and it will be copied to a spare and failed
Sun Jul 26 08:22:23 CEST [node_name: config_thread: raid.rg.diskcopy.start:notice]: /aggregate/plex0/rg2: starting disk copy from 0a.22.14 to 4a.22.17. Reason: Disk replace was started..
Sun Jul 26 08:22:23 CEST [node_name: config_thread: raid.config.filesystem.disk.failed:error]: File system Disk /aggregate/plex0/rg2/0a.22.14 Shelf 22 Bay 14 [NETAPP X422_HCOBE600A10 NA02] S/N [XXXXXXXX] UID [xxxxxxxx:xxxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] failed.
Sun Jul 26 08:22:23 CEST [node_name: disk_admin: disk.failmsg:notice]: Disk 0a.22.14 (XXXXXXXX): Predictive Failure PFA (0x01), ASC(0x5d), ASCQ(0x90), FRU(0x90). 3194641 Disk 0a.22.14 Shelf 22 Bay 14 [NETAPP X422_HCOBE600A10 NA02] S/N [XXXXXXXX] UID [xxxxxxxx:xxxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
Sun Jul 26 08:22:23 CEST [node_name: dmgr_thread: raid.notify.on.failure:debug]: Received SDM_NOTIFY_ON_FAILURE for disk uid xxxxxxxx:xxxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000, originating sysid 536877193, with failure reason 1 (failed).
Sun Jul 26 08:22:23 CEST [node_name: config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf 22, Bay 14, Model [X422_HCOBE600A10], S/N [XXXXXXXX]