While running diagnostics from boot_diags on the AFF A800, fans 1 and 7 show as failed.  Output will look similar to the following:

============================================================
Fan Test:
============================================================

Set all fan to 60% Duty cycle
23000 * 60% = 13800
Check RPM in the range from 12420 to 15180 RPM
FAN_1 expect In range from 12420 to 15180 RPM, current 13648 RPM, result: pass
FAN_2 expect In range from 12420 to 15180 RPM, current 13573 RPM, result: pass
FAN_3 expect In range from 12420 to 15180 RPM, current 13501 RPM, result: pass
FAN_4 expect In range from 12420 to 15180 RPM, current 13604 RPM, result: pass
FAN_5 expect In range from 12420 to 15180 RPM, current 13602 RPM, result: pass
FAN_6 expect In range from 12420 to 15180 RPM, current 13575 RPM, result: pass
FAN_7 expect In range from 12420 to 15180 RPM, current 13607 RPM, result: pass
FAN_8 expect In range from 12420 to 15180 RPM, current 13482 RPM, result: pass
FAN_9 expect In range from 12420 to 15180 RPM, current 13548 RPM, result: pass
FAN_10 expect In range from 12420 to 15180 RPM, current 13657 RPM, result: pass
Set all fan to 80% Duty cycle
23000 * 80% = 18400
Check RPM in the range from 16560 to 20240 RPM
FAN_1 expect In range from 16560 to 20240 RPM, current 13641 RPM, result: fail
FAN_2 expect In range from 16560 to 20240 RPM, current 18021 RPM, result: pass
FAN_3 expect In range from 16560 to 20240 RPM, current 18192 RPM, result: pass
FAN_4 expect In range from 16560 to 20240 RPM, current 18179 RPM, result: pass
FAN_5 expect In range from 16560 to 20240 RPM, current 18063 RPM, result: pass
FAN_6 expect In range from 16560 to 20240 RPM, current 18161 RPM, result: pass
FAN_7 expect In range from 16560 to 20240 RPM, current 13591 RPM, result: fail
FAN_8 expect In range from 16560 to 20240 RPM, current 18009 RPM, result: pass
FAN_9 expect In range from 16560 to 20240 RPM, current 18103 RPM, result: pass
FAN_10 expect In range from 16560 to 20240 RPM, current 18036 RPM, result: pass
Load default fan table

RESULT: FAILED

System Test Summary:
     CPU       : PASSED
     TPM       : PASSED
     Eth       : PASSED
     BMC       : PASSED
     PSU       : PASSED
     PCH-I2C   : PASSED
     RTC       : PASSED
     Quad Port 10GbE NIC Slot 4     : PASSED
     Quad Port 10GbE NIC Slot 5     : PASSED
     Mezzanine Dual Port 100GbE NIC : PASSED
     FAN       : FAILED

 

Swapping around "failed" fans with working fans and then retesting will still show fans 1 and 7 failed.

 

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support

 

******************************************************* *******************************************************