Issue

  • AutoSupport message is triggerred:

 Notification (BATTERY (full charge capacity low)) EMERGENCY.

  • EMS log reports an error and recovers automatically:

Fri Feb 14 13:50:52 GMT [node_name: env_mgr: nvmem.battery.fccLowCrit:EMERGENCY]: The NVMEM battery full-charge capacity is critically low (30 ). To prevent data loss, the system will shut down in 20 minutes.

  • This is a false alert message if the following is seen shortly after the alert:

Fri Feb 14 13:54:53 GMT [node_name: env_mgr: nvmem.battery.fccNormal:notice]: The NVMEM battery full-charge capacity is normal.

  •  SP-LATEST-SYSTEM-EVENT-LOG indicate that a learning cycle is taking place at the time of the messages.

Record 835: Fri May 22 12:00:13 2020 [IPMI.notice]: f000 | 02 | EVT: 0301ffff | Bat_Lrn_Active | Assertion Event, "State Asserted"

Record 841: Fri May 22 18:08:41 2020 [IPMI.notice]: f500 | 02 | EVT: 0300ffff | Bat_Lrn_Active | Assertion Event, "State Deasserted"

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.