Issue

  • When running command fcp adapter show -node xxxx -adapter xx the following is observed:
  • Operational Status: offline
  • Extended Status: ADAPTER DOWN DUE TO SYSTEM
  • Error: show failed: Timeout while getting fabric information"
  • EMS / event log show has errors and alerts related to the adapter port
  • Adapter reinitialization fails (example):

[NODE-02: fct_tpd_thread_0: scsitarget.hwpfct.errorReset:notice]: An error was encountered in the FC target driver on Fibre Channel target adapter 5a. The adapter will be automatically reset to clear the Depletion of Driver MQ condition.
[NODE-02: fct_tpd_thread_0: fcp.io.status:debug]: STIO Adapter 5a resetting with 0 ITN and 0 commands to drain.
[NODE-02: nvmf_master_0: nvmf.spdk.err:debug]: fc_adm_api.c:1448 Hw port 0 already offline. err = 2
[NODE-02: fct_tpd_thread_0: scsitarget.hwpfct.initFailed:alert]: Initialization of adapter failed on Fibre Channel target adapter 5a.
[NODE-02: fct_tpd_thread_0: scsitarget.fct.port.offline:error]: Fibre Channel Target port 5a was taken operationally offline due to too many errors received by the FCT driver.
[NODE-02: fct_tpd_thread_0: fcp.io.status:debug]: STIO Adapter 5a reinitialization failed, saving RAS trace data.

  • IO WQE failure (example):

[NODE-02: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:5a IO WQE failure, Handle 0x0, Type 8, S_ID: 610601, VPI: 3, OX_ID: 18D, Status 0x3 Ext_Status 0x16

 

Follow the below steps to narrow down the issue

  • Identify initiator by using the S_ID (source ID)to correlate with respective entries in switch log or EMS log (via event log show or ActiveIQ AutoSupports)
  • Find the respective initiator login or switch log entry: [NODE-02: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '5a' by initiator port: 'WWPN​​​​​' address 0xS_ID. The target virtual port is: 'NetApp FC Target Port (LPe32000) svm-NAME:NODE-02_fc_lif_1'.​​​
  • Verify all physical components of the connection end to end are are healthy, Identify reason and remedy factor causing aborts/resets resulting in fcp.io.status:debug messages.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.