Skip to main content
NetApp Knowledge Base

FAS9000/AFF-A700 PCI NMI panics again after CNA replacement

Views:
1,206
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • AFF-A700
  • FAS9000
  • Above models must have CNA card model X91143A
  • ONTAP 9

Issue

The FAS9000 or AFF-A700 systems triggers a PCI NMI error and results in a system reboot

  • The Service Processor (SP) system log displays the following error:

Example:

Panic String: PCI Error NMI from device(s):ErrSrcID(CorrSrc(0x8460),UCorrSrc(0)), RPT(128,2,0):PLX PCIE 8780 switch on Controller, Br[8780](132,12,0): Link down.  in process idle: cpu24 on release 9.6P3 (C)

  • From the "sysconfig -PCI" command output, it is determined that the link was down between the Motherboard and the card in slot 7.

Example:

Br[8780](132,12,0): PLX PCIE 8780 switch on Controller
 LinkCap(MaxLkSp(3),MaxLkWd(16),ASPM(2),L0(6),L1(2),SurpDn,DLAct,Port(12))
 LinkStatus(LkSp(3),LkWd(16),DLAct),   
               Br[8732](137,0,0) in slot 7: PLX PCIE 8732 switch in slot 7 on Controller
                LinkCap(MaxLkSp(3),MaxLkWd(16),ASPM(2),L0(6),L1(2),Port(0))
                LinkStatus(LkSp(3),LkWd(16)),   

  •  "sysconfig -ac" shows details of the card in slot 7.

Example:

sysconfig: slot 1 OK: X91143A: Qlogic EP8324 Quad-Port 16Gb FC/10GbE PCIe CNA
sysconfig: slot 2 OK: X91143A: Qlogic EP8324 Quad-Port 16Gb FC/10GbE PCIe CNA
sysconfig: slot 3 OK: X91143A: Qlogic EP8324 Quad-Port 16Gb FC/10GbE PCIe CNA
sysconfig: slot 4 OK: X91440A: 40G high performance
sysconfig: slot 6 OK: X93140A: NetApp NVRAM10
sysconfig: slot 7 OK: X91143A: Qlogic EP8324 Quad-Port 16Gb FC/10GbE PCIe CNA
sysconfig: slot 9 OK: X92071A: PMC PM8072; PCI-E quad-port SAS (PM8072)
sysconfig: slot 10 OK: X91143A: Qlogic EP8324 Quad-Port 16Gb FC/10GbE PCIe CNA
sysconfig: slot 11 OK: X91143A: Qlogic EP8324 Quad-Port 16Gb FC/10GbE PCIe CNA

  • The CNA card in the slot is replaced, and at some point afterwards the controller panics again with the same panic string from the same slot

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.