FAS26xx and FAS27xx controller running in Single-Path HA with no external shelf
Applies to
- FAS26xx/AFF-A200
- FAS27xx/AFF-C190/AFF-A220
Issue
FAS26xx or FAS27xx system with no external disk shelves, the user may notice that the system is operating in Single-Path HA mode when checked in
sysconfig -a
NetApp Release 9.9.1: Sun Jun 13 07:48:38 EDT 2021
System ID: xxxxxxxxxx (xxxxxxxxxx); partner ID: xxxxxxxxxx(xxxxxxxxxx)
System Serial Number: xxxxxxxxxxxx (xxxxxxxxxx)
System Rev: D0
System Storage Configuration: Single-Path HA
System ACP Connectivity: Inband Active
SAS2/SAS3 Mixed Stack Support: all
All-Flash Optimized: false
Capacity Optimized: false
All SAN Array: false
Backplane Part Number: DS21212
Backplane Rev:
Backplane Serial Number: xxxxxxxxxxxx
slot 0: System Board 1.5 GHz (System Board XXII D0)
Model Name: FAS2720
Part Number: 111-04333
Revision: D0
Serial Number: xxxxxxxxxxxx
BIOS version: 11.11
Loader version: 6.0.12
Processors: 12
Processor ID: 0x50664
Microcode Version: 0xf000016
Processor type: Intel(R) Xeon(R) CPU D-1557 @ 1.50GHz
Memory Size: 32768 MB
Memory Attributes: Hoisting
Rank Interleaving
Channel Interleaving
Mezzanine Card:
Part: 111-04160
Version: A1
Serial: xxxxxxxxxxxx
NVMEM Size: 4094 MB of Main Memory Used
Controller: A
PCIE Switch 1: id 1 546 1.04
TPM FW Version: 5.63.3353.0
Service Processor Status: Online
Firmware Version: 11.6
Mgmt MAC Address: xx:xx:xx:xx:xx:xx
Ethernet Link: up, full duplex, auto-neg complete
Using DHCP: no
IPv4 configuration:
IP Address: xxx.xxx.xxx.xxx
Netmask: xxx.xxx.xxx.xxx
Gateway: xxx.xxx.xxx.xxx
IPv6 configuration: Disabled
[Service Processor cached network information determined at Tue Dec 14 07:57:40 UTC 2021]
slot 0: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <OFFLINE (hard)>)
Firmware rev: 03.08.09.00
Base WWN: 5:00a098:00e8102:b0
Temperature: Not Available
Phy State: [0] Disabled
[1] Disabled
[2] Disabled
[3] Disabled
Mini-SAS HD Vendor: not available
Mini-SAS HD Part Number: not available
Mini-SAS HD Type: not available
Mini-SAS HD Serial Number: not available
slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
Firmware rev: 03.08.09.00
Base WWN: 5:00a098:00e8102:b4
Temperature: Not Available
Phy State: [4] Enabled, 12.0 Gb/s
[5] Enabled, 12.0 Gb/s
[6] Enabled, 12.0 Gb/s
[7] Enabled, 12.0 Gb/s
00.0 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.1 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.2 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.3 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.4 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.5 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.6 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.7 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.8 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.9 : NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.10: NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
00.11: NETAPP X318_SCMNE08TA07 NA00 7486.1GB 520B/sect (xxxxxxxx)
Shelf 0: DS212-12 Firmware rev. IOM12E A: 0230 IOM12E B: 0230