Skip to main content
NetApp Knowledge Base

Environmental Reason Shutdown (Battery PCT capacity critical)

Views:
496
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS2720
  • FAS2750
  • C190

Issue

FAS27xx system hits emergency shutdown with reason "Battery PCT capacity critical".
 
Jan 02 21:43:08 [nodename:nvmem.battery.fccLowCrit:EMERGENCY]: The NVMEM battery full-charge capacity is critically low (15 ). To prevent data loss, the system will shut down in 20 minutes.
Jan 02 21:43:59 [nodename:nvmem.battery.capLowCrit:EMERGENCY]: The NVMEM battery capacity is critically low (0 cycles). To prevent data loss, the system will shut down in 20 minutes.
Jan 02 21:44:08 [nodename:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (full charge capacity low) CRITICAL.
Jan 02 21:44:29 [nodename:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (capacity low) CRITICAL.
Jan 02 22:00:00 [nodename:monitor.nvramLowBattery:EMERGENCY]: NVRAM battery is dangerously low.
Jan 02 22:03:09 [nodename:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery PCT capacity critical)
Waiting for PIDS: /usr/sbin/rpcbind 1208.
Terminated
.
Uptime: 117d7h1m47s
System powering down...

 