Issue

  • SP events all reports battery temperature errors and battery pack invalid errors.

[IPMI.notice]: 3301 | 02 | EVT: 0301ffff | Bat_Lrn_Active | Assertion Event, "State Asserted"
[IPMI.notice]: 3401 | 02 | EVT: 0150ef05 | Bat_Temp | Assertion Event, "Lower Non-critical going low "
[IPMI.notice]: 3501 | 02 | EVT: 0152ef00 | Bat_Temp | Assertion Event, "Lower Critical going low "
[IPMI.notice]: 3601 | 02 | EVT: 0301ffff | Bat_Pack_Invalid | Assertion Event, "State Asserted"
[IPMI.notice]: 3701 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
[IPMI.notice]: 3801 | 02 | EVT: 0300ffff | Attn_Sensor1 | Assertion Event, "State Deasserted"
[IPMI.notice]: 3901 | 02 | EVT: 81522e00 | Bat_Temp | Deassertion Event, "Lower Critical going low "
[IPMI.notice]: 3a01 | 02 | EVT: 81502e05 | Bat_Temp | Deassertion Event, "Lower Non-critical going low "
[IPMI.notice]: 3b01 | 02 | EVT: 0300ffff | Bat_Pack_Invalid | Assertion Event, "State Deasserted"
[IPMI.notice]: 3c01 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
[IPMI.notice]: 3d01 | 02 | EVT: 0150ef05 | Bat_Temp | Assertion Event, "Lower Non-critical going low "
[IPMI.notice]: 3e01 | 02 | EVT: 0152ef00 | Bat_Temp | Assertion Event, "Lower Critical going low "
[IPMI.notice]: 3f01 | 02 | EVT: 0301ffff | Bat_Pack_Invalid | Assertion Event, "State Asserted"
[IPMI.notice]: 4001 | 02 | EVT: 0300ffff | Attn_Sensor1 | Assertion Event, "State Deasserted"

  • EMS log reports sensor 15 temperature error from both HA nodes.

nvmem.battery.tempLow:alert]: The NVMEM battery is too cold (-17 C). To prevent data loss, the system will shut down in 24 hours.

nvmem.battery.temp.normal:info]: The NVMEM battery temperature is normal.

nvmem.battery.packValid:notice]: A valid NVMEM battery pack is present.

ses.status.temperatureWarning:alert]: DS212-12 (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0a temperature warning for Temperature sensor 15: not installed or failed. Current temperature: 46 C (114 F). `O\252\207r.

ses.status.temperatureInfo:info]: DS212-12 (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0a temperature information for Temperature sensor 15: normal status.

 

ses.status.temperatureWarning:alert]: DS212-12 (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0b temperature warning for Temperature sensor 15: not installed or failed. Current temperature: 46 C (114 F). `O\252\207r.

ses.status.temperatureInfo:info]: DS212-12 (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0b temperature information for Temperature sensor 15: normal status.

  • The error has recovered in around 30 seconds.
  • From SP-LATEST-IPMI, a battery learning cycle was taking place during this error.

LrnCycleStartDate : 22-03-17-12:00

LrnCycleStartFCC  : 0x0546

LrnCycleEndFCC    : 0x054e

LrnCycleEndDate   : 22-03-17-22:59

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.