Skip to main content
NetApp Knowledgebase

EMS log reports "nvmem.battery.fccLowCrit:EMERGENCY" error

Views:
302
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9.1P16
  • FAS2650
  • Service Processor(SP) 5.1P3

Issue

  • EMS log reports the following error and recovers automatically.

         Example:

[?] Fri May 22 22:56:53 JST [node: env_mgr: nvmem.battery.fccLowCrit:EMERGENCY]: The NVMEM battery full-charge capacity is critically low (30 ). To prevent data loss, the system will shut down in 20 minutes.
[?] Fri May 22 22:57:49 JST [node: env_mgr: callhome.battery.failure:EMERGENCY]: Call home for BATTERY (full charge capacity low) CRITICAL.
[?] Fri May 22 23:02:55 JST [node: env_mgr: nvmem.battery.fccNormal:notice]: The NVMEM battery full-charge capacity is normal.

 

  • The SP-LATEST-SYSTEM-EVENT-LOG indicate that a learning cycle is taking place at the time of the messages.

Example:

Record 835: Fri May 22 12:00:13 2020 [IPMI.notice]: f000 | 02 | EVT: 0301ffff | Bat_Lrn_Active | Assertion Event, "State Asserted"

Record 841: Fri May 22 18:08:41 2020 [IPMI.notice]: f500 | 02 | EVT: 0300ffff | Bat_Lrn_Active | Assertion Event, "State Deasserted"
 

 