Skip to main content
NetApp Knowledge Base

Call home for BATTERY (capacity low) CRITICAL

Views:
3,357
Visibility:
Public
Votes:
2
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

  • Service Processor (SP)
  • AFF A700
  • AFF A220
  • FAS 2720
  • FAS 2750
  • AFF C190

Issue

  • EMS reports "BATTERY (capacity low) CRITICAL".

Example:

[NodeA:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (capacity low) CRITICAL.

  • Check system sensors show in SP, the status of battery is normal.

Example:

Bat_Status       | 0x0        | discrete   | Ready      | na        | na        | na        | na        
Bat_Ambient_1    | 25.000     | degrees C  | ok         | 0.000     | 3.000     | 47.000    | 52.000    
Bat_Ambient_2    | 25.000     | degrees C  | ok         | 0.000     | 3.000     | 47.000    | 52.000    
Bat_Charge_Curr  | 0.000      | Amps       | ok         | na        | na        | 5.500     | 6.000     
Bat_Charge_Volt  | 8.150      | Volts      | ok         | na        | na        | 8.350     | 8.400     
Bat_Curr         | 0.000      | Amps       | ok         | -0.100    | -0.050    | 2.500     | 3.000     
Bat_Cycle_Count  | 12.000     | cycles     | ok         | na        | na        | na        | na        
Bat_Design_Cap   | 4.300      | Amps*hour  | ok         | 0.000     | 0.000     | 6.375     | 6.375     
Bat_Dstg_Cycles  | 12.000     | cycles     | ok         | 2.000     | 5.000     | na        | na        
Bat_Full_Cap     | 3.025      | Amps*hour  | ok         | 2.000     | 2.200     | 4.750     | 5.000     
Bat_Initial_Fcc  | 3.275      | Amps*hour  | ok         | 2.000     | 2.200     | 4.750     | 5.000     
Bat_Rem_Cap      | 3.025      | Amps*hour  | ok         | 0.250     | 0.500     | 4.750     | 5.000     
Bat_Temp         | 24.000     | degrees C  | ok         | -5.000    | 0.000     | 55.000    | 60.000    
Bat_Volt         | 8.150      | Volts      | ok         | 6.000     | 6.500     | 8.300     | 8.500  

  • "Learn cycle" is recorded in "events all" of SP.

Example:

Record 1552: Mon Feb 22 00:21:19.602467 2021 [IPMI.notice]: 7d04 | 02 | EVT: 6f08ffff | Bat_Status | Assertion Event, "Learn Cycle"
Record 1553: Mon Feb 22 01:31:20.286318 2021 [IPMI.notice]: 7e04 | 02 | EVT: ef08ffff | Bat_Status | Deassertion Event, "Learn Cycle"

  • EMS reports "nvram.battery.current.normal"

Example:

[?] Thu Sep 02 06:17:01 UTC [NodeA: env_mgr: nvram.battery.current.normal:info]: The NVRAM battery current is normal.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.