In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Call home for BATTERY ('Bat Initial FCC' unreadable) CRITICAL

Views:
531
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • FAS 8060
  • AFF 8060

Issue

After motherboard replacement, ONTAP reports the following error messages during the boot process:
 
Oct 07 18:27:07 [SYD2SISFAS02:nvram.battery.sensor.unreadable:EMERGENCY]: The NVRAM battery state cannot be determined because the 'Bat Initial FCC' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
Oct 07 18:27:37 [SYD2SISFAS02:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Initial FCC' unreadable) CRITICAL.

Wed Oct  7 12:50:11 GMT [nvram.hw.initFail:CRITICAL]: NVRAM hardware initialization failed: DDR DIMM is not present or failed to train.
******************************************************************
*                         CRITICAL ERROR                         *
* NVRAM has detected errors. Ontap cleared the error.            *
* Data loss is likely.                                           *
******************************************************************

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support

 

  • Was this article helpful?