Applies to

  • FAS8200
  • AFF A300

Issue

  • CPU0_Error "State Asserted" and "State Deasserted" are reported repeatedly from Service Processor (SP) events all. Attention LED may be lit on impacted node.

Record 1532: Fri Mar 26 03:45:32 2021 [IPMI.notice]: a403 | 02 | EVT: 0300ffff | CPU0_Error | Assertion Event, "State Deasserted"
Record 1533: Fri Mar 26 03:45:39 2021 [IPMI.notice]: a503 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
Record 1534: Fri Mar 26 03:47:32 2021 [IPMI.notice]: a603 | 02 | EVT: 0300ffff | CPU0_Error | Assertion Event, "State Deasserted"
Record 1535: Fri Mar 26 03:47:39 2021 [IPMI.notice]: a703 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
Record 1536: Fri Mar 26 03:47:46 2021 [IPMI.notice]: a803 | 02 | EVT: 0300ffff | CPU0_Error | Assertion Event, "State Deasserted"
Record 1537: Fri Mar 26 03:47:53 2021 [IPMI.notice]: a903 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
Record 1538: Fri Mar 26 03:48:07 2021 [IPMI.notice]: aa03 | 02 | EVT: 0300ffff | CPU0_Error | Assertion Event, "State Deasserted"
Record 1539: Fri Mar 26 03:48:14 2021 [IPMI.notice]: ab03 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
Record 1540: Fri Mar 26 03:48:28 2021 [IPMI.notice]: ac03 | 02 | EVT: 0300ffff | CPU0_Error | Assertion Event, "State Deasserted"
Record 1541: Fri Mar 26 03:48:42 2021 [IPMI.notice]: ad03 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"

  • Issue remains after SP reboot.

Record 1695: Thu Jan  1 00:00:41 1970 [IPMI.notice]: bf03 | c0 | OEM: ffff70005000 | ManufId: 150300 | SP Reset Externally
Record 1696: Thu Jan  1 00:00:41 1970 [IPMI.notice]: c003 | c0 | OEM: fcff70000000 | ManufId: 150300 | POS Register: Unexpected Reset
Record 1697: Thu Jan  1 00:00:50 1970 [IPMI.notice]: c103 | 02 | EVT: 0301ffff | CPU0_Error | Assertion Event, "State Asserted"
Record 1698: Thu Jan  1 00:00:55 1970 [IPMI.notice]: c203 | 02 | EVT: 0300ffff | Fan_Override | Assertion Event, "State Deasserted"

  • From system sensors show !normal output, CPU Error is in fault status.

Cluster::> sensors show -state !normal
  (system node environment sensors show)
Node Sensor
         State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- --------
------- -------
node-1
     CPU0 Error             fault
                                        ERROR

  • From SP system sensors CPU0 status are in Asserted status.

Sensor Name      | Current    | Unit       | Status     | LCR       | LNC       | UNC       | UCR
-----------------+------------+------------+------------+-----------+-----------+-----------+-----------
CPU0_Temp_Margin | -60.000    | degrees C  | ok         | na        | na        | -10.000   | 0.000     
In_Flow_Temp     | 21.000     | degrees C  | ok         | 0.000     | 5.000     | 50.000    | 55.000    
Out_Flow_Temp    | 34.000     | degrees C  | ok         | 0.000     | 5.000     | 65.000    | 75.000    
PCI_Slot_Temp    | 30.000     | degrees C  | ok         | 0.000     | 5.000     | 60.000    | 70.000    
Smart_Bat_Temp   | 28.000     | degrees C  | ok         | 0.000     | 5.000     | 60.000    | 70.000    
CPU0_Error       | 0x0        | discrete   | Asserted   | na        | na        | na        | na              

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.