Skip to main content
NetApp Knowledge Base

CN1610 cluster switch rebooting due to Oops: Machine check, sig: 7

Views:
31
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

CN1610

Issue

  • CN1610 is constantly rebooting
  • Console logs of switch show the following: Oops: Machine check, sig: 7 [#1]
Oops: Machine check, sig: 7 [#1]
cord8541
Modules linked in: linux_user_bde(PO) linux_kernel_bde(PO)
NIP: 10486064 LR: 1051e1ec CTR: 10485ee8
REGS: c3fe7f10 TRAP: 0204   Tainted: P           O  (3.8.13-2de1cc1c)
MSR: 0002d000 <ce,ee,pr,me>  CR: 40002444  XER: 20000000
TASK = c3f22be0[337] 'bcmINTR' THREAD: c3fe6000
GPR00: 1051e1ec 483a8ca0 483b0920 00008001 ffffffff 40002444 00008000 00000000
GPR08: 00008000 481e2000 80000000 0ff44290 c3fe6000 12d039d0 00000000 00000000
GPR16: 00008000 1329ccd4 1329ccd4 00000000 11b1471c 10450000 00038008 00000000
GPR24: 000b807f 122d5aa8 122d5998 000186a0 000186a0 1320f7d8 00000000 00000000
NIP [10486064] 0x10486064
LR [1051e1ec] 0x1051e1ec
Call Trace:
---[ end trace 60d878106f5e0684 ]---

Kernel panic - not syncing: Fatal exception
Rebooting in 15 seconds..
Restarting Corduroy CS.

 