In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Automatic SP upgrade fails after ONTAP upgrade on AFF A300 and FAS8200

Views:
2,765
Visibility:
Public
Votes:
1
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • AFF-A300
  • FAS8200
  • ONTAP 9
  • SP versions affected 5.6, 5.7, 5.8

Issue

  • After completing ONTAP upgrade bundled with newer SP firmware, the automatic SP upgrade fails and remains on previous version.
Example:

::> event log show -node * -message-name sp.servprocd.upd.error

Node3    ERROR         sp.servprocd.upd.error: SP update error: SP firmware update failure has been detected.
Node2    ERROR         sp.servprocd.upd.error: SP update error: SP firmware update failure has been detected.
Node6    ERROR         sp.servprocd.upd.error: SP update error: SP firmware update failure has been detected.
Node5    ERROR         sp.servprocd.upd.error: SP update error: SP firmware update failure has been detected.

SP-MGMT-MLOG-TXT log (Can be viewed from Active IQ digital Advisor)

Click here to access Active IQ Digital Advisor

[kern_servprocd:info:6905] 0x809878700: 0: NOTICE: Servprocd::SpUpdate: update: SP firmware image for network transfer has been created.
kern_servprocd:info:6905] 0x809878700: 0: NOTICE: Servprocd::SpUpdate: transferImage: sending /mroot/etc/RLM_FW/sp_image.tar.gz to SP, destination: /tmp/sp_image.tar.gz.
[kern_servprocd:info:6905] 0x809878700: 0: ERR: Servprocd::SpUpdate: transferImage: FTM sp_send_file failed to transfer /mroot/etc/RLM_FW/sp_image.tar.gz to SP. Error 26. Sleep for 30 secs and retry. Retry count : 1
[kern_servprocd:info:6905] 0x809878700: 0: NOTICE: Servprocd::SpUpdate: transferImage: sending /mroot/etc/RLM_FW/sp_image.tar.gz to SP, destination: /tmp/sp_image.tar.gz.
[kern_servprocd:info:6905] 0x809878700: 0: ERR: Servprocd::SpUpdate: transferImage: FTM sp_send_file failed to transfer /mroot/etc/RLM_FW/sp_image.tar.gz to SP. Error 26. Sleep for 30 secs and retry. Retry count : 2

  • EMS logs show SPLinkDownAlert:

Example:

nphmd hm alert raised: detailed_info="Alert Id = SPLinkDownAlert , Alerting Resource = SP Config" monitor="controller" alert_id="SPLinkDownAlert" alerting_resource="SP Config"

  • Rebooting SP due to low memory from SP event log:

Example:

Record 848: Sat May 29 05:47:21 2021 [IPMI.critical]: Rebooting SP due to low memory
Record 849: Thu Jan  1 00:00:46 1970 [IPMI.notice]: 7a00 | c0 | OEM: ffff70005100 | ManufId: 150300 | SP Reset Internally

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support