Skip to main content
NetApp Knowledgebase

Auto Support Alert:callhome.hm.alert.critical:Call home for Health Monitor process nphm: CriticalCECCCountMemErrAlert[DIMM-4]

Views:
220
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • AFF-A300
  • ONTAP 9.1P13

Issue

  • EMS raises “CriticalCECCCountMemErrAlert” error.

Example:

Sat May 30 12:12:45 UTC [hostname: mgwd: callhome.hm.alert.critical:alert]: Call home for Health Monitor process nphm: CriticalCECCCountMemErrAlert[DIMM-4].

  • In ASUP Health Alert, the “Correctable ECC error count” is over 500 times.

 Example:

Slot Name: DIMM-4
CPU Socket: 0
Channel: 1
Slot number on a channel: 1
Correctable ECC error count: 506
Uncorrectable ECC error count: 0

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support