Skip to main content
NetApp Knowledge Base

Amber LED on disk

Views:
40
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • DS224C
  • FAS2650
  • FAS2750

Issue

  • The light of disk is amber, but there is no error reported by ONTAP
  • storage show fault command returns no faults
 
::> system node run -node  Node-01 -command storage show fault
No faults found in storage subsystem
 
  • Verbose output of the same command shows the disk as having been bypassed by both IOMs
 
system node run -node Node-01 -command storage show fault -v

Node: Node-01

Enclosure Status: non-critical
Channel: 0a
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: SHFHUXXXXXXXXXX
Module Type: IOM12E

Disk Elements:
Element Status                  Status Bytes  Status Descriptions
0 [Bay  0]: OK                    01,00,00,00
1 [Bay  1]: OK                    01,01,00,00
2 [Bay  2]: OK                    01,02,00,00
3 [Bay  3]: NONCRITICAL           03,0A,20,08   ENCLOSURE BYPASSED A, BYPASSED A