Amber LED of SAS port is ON without any error
Applies to
- FAS8300/AFF A400
- ONTAP 9
Issue
Amber LEDs of SAS ports (0a, 0b, 0c, 0d) are ON without any error.
- Output of
sysconfig -a
shows port 0a & 0d are cables connected and functioning correctly.
slot 0: SAS Host Adapter 0a (Broadcom SAS3616W rev. 2, SAS, <UP>)
Firmware rev: 12.00.00.00
NVDATA rev: 12.03.01.02
Base WWN: 5:00a098:00e4976:40
Phy State: [0] Enabled, 12.0 Gb/s
[1] Enabled, 12.0 Gb/s
[2] Enabled, 12.0 Gb/s
[3] Enabled, 12.0 Gb/s
Mini-SAS HD Vendor: Molex Inc.
Mini-SAS HD Part Number: 112-00437+A0
Mini-SAS HD Type: Passive Copper (unequalized) 2m end_1
Mini-SAS HD Serial Number: 023330042
- BMC command
system fru led show all
shows attention(amber) LED is ON.
BMC node-02> system fru led show all
0 LED_SYSTEM_LOCATION_01 is off
1 LED_SYSTEM_ATTEN_01 is off
2 LED_CONTROLLER_ATTEN_01 is off
......
9 LED_SAS_ATTEN_01 is on <-- SAS port 0a
10 LED_SAS_ATTEN_02 is on <-- SAS port 0b
11 LED_SAS_ATTEN_03 is on <-- SAS port 0c
12 LED_SAS_ATTEN_04 is on <-- SAS port 0d