Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

"Active IQ Config Advisor Summary Report " reports "SAS Cabling checks"

Views:
243
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

AFF-A700s

ONTAP 9.7P4

Issue

  • "Active IQ Config Advisor Summary Report " reports "SAS Cabling checks".

Example:

Description:SAS Cabling Checks
Severity :High Impact
Details :Three paths found from controller node name:******* to the stack on port 0a. Only multipath and quad-path configurations are supported.

  • "sysconfig -a" log shows  quad-path is normal.

Example:

slot 0: SAS Host Adapter 0a (Avago Technologies SAS3008 rev. 2, SAS, <UP>)
  Firmware rev:      13.00.00.00
  NVDATA rev:        11.02.17.08
  Base WWN:          5:00a098:00e3028:84
  Phy State:         [0] Enabled, 12.0 Gb/s
                     [1] Enabled, 12.0 Gb/s
                     [2] Enabled, 12.0 Gb/s
                     [3] Enabled, 12.0 Gb/s

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support