In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

AFF-A700/FAS9000 reporting NVRAM boot error messages and LEDs ON but without real errors

Views:
935
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • FAS9000
  • AFF A700  

Issue

  • After a NVDIMM replacement in a FAS9000 or AFF A700, the system is still reporting: 

    ::> system controller service-event show -instance
    Node: NODE_NAME
    Service Event ID: 1
    Location: NVDIMM 1 on PCI 6
    Description: NVDIMM1:UECC detected
    Timestamp: Wed May 30 12:20:03 2018
    
    Node: NODE_NAME
    Service Event ID:2
    Location: NVDIMM 2 on PCI6
    Description: NVDIMM2: UECC detected
    Timestamp: Wed May 30 12:20:04 2018
    2 entries were displayed.
    
  • Boot process messages, in the console logs: 

================ Log #9 start time Tue Jun 5 14:57:30 2018 NetAppData ONTAP 9.3P4 ******************************************************* WARNING: The NVRAM DIMM1 has caused UECC in the past. Please replace it as soon as possible!!! *************************** WARNING: The NVRAM DIMM2 has caused UECC in the past. Please replace it as soon as possible!!! ****************************************************** 

  • SP events:  

Record 2434: Mon Nov 05 16:34:50.052098 2018 [IPMI.notice]: d001 | 02 |EVT: ef02ffff | NVS_Status | Deassertion Event, "Fault"

Record 141: Mon Dec 17 15:42:02.523180 2018 [IPMI.notice]: ac02 | 02 |EVT: 6f02ffff | NVS_Status | Assertion Event, "Fault" < - - - After the power off/on 

  • SP events: 

SP NODE_NAME> system service-event show
ID FRU Description Fault
Reason
--------------------------- -------
-----------
1 NVDIMM 1 on PCI 6
NVDIMM1: UECC detected
2 NVDIMM 2 on PCI 6
NVDIMM2: UECCdetected
Fault Lights On:
/chassis-1
PCI 6
NVDIMM 1 on PCI 6
NVDIMM 2 on PCI 6

  • No UECC / NVRAM messages being reported by the EMS logs

 

 

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support