ATTO 7500N/7600N will not boot with Critical Software Error Detected by duplicate IP Address
Applies to
- ATTO FibreBridge 7500N
- ATTO FibreBridge 7600N
- Unsecured FibreBridge(s)
Issue
After rebooting after a firmware upgrade, the bridge went into a reboot loop. The bridge also reported a Duplicate IP address.
Detected duplicate IP Address: 10.0.0.2 on Management Port: MP2.
Example:
011191 22:10:42 CRIT-Address 10.0.0.2 for MP1 already in use
011192 22:10:42 CRIT-Software Interrupt Exception Detected (SWI) (007A)
011193 22:10:42 CRIT-Instr Address = 00396b3c
011194 22:10:42 CRIT-SWI Number = 0x000000
011195 22:10:42 INFO-Software Interrupt
0111A4 00:00:05 INFO Reset. HW Code: Software Warm
0111A5 00:00:05 INFO Reset. Reason: Critical Software Error Detected
0111A6 22:12:15 SYS System date has changed. Current date:[08/19/2020]
0111A7 22:12:15 INFO Boot/reset occurred (007A)
0111A8 22:12:15 INFO Checkpoint 33 B:0 S0:0:0 S1:0:0 D0:0 C:0 O:0 I:0