Skip to main content
NetApp Knowledge Base

"sysconfig -a" reports Shelf Serial Number instead of Shelf ID after IOM reseat/replacement

Views:
692
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

Applies to

  • IOM shelf modules
  • Data ONTAP all version

Issue

After reseating or replacing an IOM module, you might observe the following anomalies:

 

  • sysconfig -a displays shelf serial number instead of the shelf ID in front the disks:

        SHM09797XXXXX.0: NETAPP X411_HVIPC420A15 NA02 418.0GB 520B/sect (CWYXXX)
     
  • sasadmin expander_map might display an invalid/alternate shelf ID :

        Level 10: WWN 50050cc104fd6d3f, ID 150, Serial Number ' SHM09797XXXXX', Product 'DS424IOM3 ', Rev '0172', Slot B
 

  • You might receive a duplicate shelf ID error in the messages log:

        [sas.shelf.conflict:error]: At least two SAS disk shelves have the same disk shelf ID.

 

 