Skip to main content

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

NetApp Knowledge Base

"ADR timeout" event reported after L2 watchdog reset

Views:
1,450
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • FAS8200
  • AFF A300

Issue

Node down due to L2 watchdog timeout after an ADR (Asynchronous DRAM Refresh). events all log example:

Record 392: Sat Feb 27 03:41:59 2021 [IPMI.critical]: ADR event ID: 0 at time: 1614397319
Record 393: Sat Feb 27 03:41:59 2021 [IPMI.critical]: ADR Battery destage cycles: 19
Record 394: Sat Feb 27 03:42:01 2021 [IPMI Event.critical]: NMI
Record 395: Sat Feb 27 03:42:01 2021 [IPMI.notice]: bd00 | 02 | EVT: 6fc824ff | System_Watchdog | Assertion Event, "Timer interrupt"
Record 396: Sat Feb 27 03:42:02 2021 [IPMI Event.critical]: L2 watchdog timeout hard reset
Record 397: Sat Feb 27 03:42:02 2021 [Trap Event.critical]: hwassist l2_watchdog_reset (29)
Record 398: Sat Feb 27 03:42:02 2021 [Trap Event.critical]: SNMP l2_watchdog_reset (29)
Record 399: Sat Feb 27 03:42:02 2021 [SysFW.notice]: ADR Timeout
Record 400: Sat Feb 27 03:42:02 2021 [SysFW.notice]: ADR Timeout
Record 401: Sat Feb 27 03:42:07 2021 [IPMI.notice]: be00 | 02 | EVT: 6fc104ff | System_Watchdog | Assertion Event, "Hard reset"
Record 402: Sat Feb 27 03:42:12 2021 [SP.critical]: Filer Reboots

 