In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

What does E-Series controller 7-segment rear display SE + 23 mean?

Views:
718
Visibility:
Public
Votes:
1
Category:
e-series-systems
Specialty:
esg
Last Updated:

 

Applies to

  • NetApp StorageGRID
  • NetApp E-Series
  • E2600
  • E2700
  • E2800 & EF280
  • E5400 & EF540
  • E5500 & EF550
  • E5600 & EF560
  • E5700 & EF570
  • SANtricity Rev 11.x

Answer

  • Controller rear 7-segment displays SE or 5E  refers to start up error
  • 23 refers to default boot device not found
  • A USB device is connected to the type A connector

Controller appears offline and will be unresponsive in the shell, unless additional actions of releasing the lockdown are used.
However, it likely will transition back to the condition after reboot