In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

What does "Isolation of drive causing redundancy mismatch" mean

Views:
1,203
Visibility:
Public
Votes:
0
Category:
disk-drives
Specialty:
esg
Last Updated:

 

Applies to

E-Series

Answer

Isolation of drive causing redundancy mismatch is MEL event type 2046.

Isolation of drive causing redundancy mismatch is a data parity mismatch for which the controller firmware has been able to isolate the mismatch to a single drive. This is only possible for RAID 6 volume groups and Dynamic Disk Pools.

Typically if a drive has been isolated it can be replaced however we do want to perform troubleshooting first.