NetApp Knowledge Base

Replacement E-Series E2800 controller goes into reboot loop and locks down with OE LU status

Views:
80
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

Applies to

  • NetApp E-Series
  • E2800/EF280 controllers
  • Original controller(s) running 11.30.x SANtricity OS
  • Replacement controller running 11.70.3 or newer

Issue

  • After replacing E2800/EF280 controller in a 11.30.x setup, the replacement controller reboot loops after attempting to auto synchronize (ACS) its SANtricity OS to match the original controller (11.30.x). 
  • The following messages are logged right before reboot, which indicate the controller is attempting to ACS its firmware:

07/21/22-19:25:11 (tRAID): NOTE:  ACS: download manager is idle
07/21/22-19:25:11 (tRAID): NOTE:  ACS: autoCodeSync(): Process start. Comm Status: 1
07/21/22-19:25:11 (tRAID): NOTE:  ACS m_AltUnifiedACSMode: 0
07/21/22-19:25:11 (tRAID): NOTE:  ActiveInfo:ver='08.73.00.00' date='2022-05-16' time='17:34:16'
07/21/22-19:25:11 (tRAID): NOTE:  ACS required -sync from Drives:false
07/21/22-19:25:11 (tRAID): NOTE:  ACS waiting for image transfer
07/21/22-19:25:16 (tRAID): NOTE:  ACS m_UnifiedACSMode: 1 m_AltUnifiedACSMode: 0