Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

E-Series controller may reboot due to interaction with Brocade FC switch

Views:
135
Visibility:
Public
Votes:
0
Category:
e-series-santricity-os-controller-software
Specialty:
esg
Last Updated:

Applies to

  • E-Series controllers using 16Gb or 32Gb fibre channel host interfaces
  • Controllers running firmware prior to 8.30.4X.XX, 11.30.4, 8.40.1X.XX, and 11.40.1
  • Brocade FC switch connected to controllers

Issue

In rare cases, a controller may reboot when connected to a Brocade switch and running a controller firmware version less than listed above.
Controller may report the following in the exception log:
Page Fault errCode: 0 pc: 0xffffffff83a2b87a
_ZN3fcd13HMtlInterface12sendElsReplyEP16BUILD_SEND_FRAME + 0x4a
or
SIGSEGV Received
(with the following contained in the backtrace)
fcd::HMtlInterface::sendElsReply(BUILD_SEND_FRAME*)

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support