E-Series Temperature sensor status is UNKNOWN with the alert "MAX_TEMP_EXCEEDED"

Views:
583
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

Applies to

 E-series

Issue

  • Temperature sensor status is UNKNOWN.

Temperature sensor status:  UNKNOWN            
Location:                   Tray 99, Sensor 1  
Temperature sensor status:  UNKNOWN            
Location:                   Tray 99, Sensor 2  

  • The RECOVERY-GURU-PROCEDURES shows Failure Entry: MAX_TEMP_EXCEEDED-Recovery Failure Type Code: 8

Storage array: NetappE
Component reporting problem: Thermal sensor
Status: UNKNOWN
Location: Controller/Drive Tray 99 Tray 99, Sensor 1
Component requiring service: Temperature sensor
Tray: Controller/Drive tray 99

  • By the MEL (MAJOR-EVENT-LOG) shows the problem that occurred on the affected controller. 

A:2020/4/28 下午 04:54:04 (08:54:04) 9658 281c Maximum temperature exceeded - Tray 99 <--CRITICAL
A:2020/4/28 下午 04:54:04 (08:54:04) 9657 281c Maximum temperature exceeded - Tray 99 <--CRITICAL
A:2020/4/28 下午 04:54:04 (08:54:04) 9656 3101 Asynchronous event notification (AEN) posted for recently logged event - Tray 99, Slot A
----> Sense 6/3f/c6 = Unit Attention - Temperature sensor failed
----> FRU group: Subsystem; Tray ID: 99, Type : Temp Sensor, State: Failed

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support