Skip to main content
NetApp Knowledge Base

VVOL Provisioning: Issues with NDMP node-scope-mode

Views:
254
Visibility:
Public
Votes:
0
Category:
netapp-vasa-provider
Specialty:
virt
Last Updated:

Applies to

VASA Provider 7.x, 9.6, 9.7

Issue

When provisioning a new VVOL datastore, the following "There are no matching storage systems found for the selected SCP" warning is seen:

clipboard_efa98778e1e90b9d9000195dc3bbffb8d.png

This warning is seen when:

  • There is a storage system that matches the capabilities of the selected SCP (storage capability profile)
  • NDMP node-scope-mode is enabled on storage

When checking the VASA Provider logs (vvolvp.log), the following is seen in the getClustersForSCP workflow:

08/07/20 EDT 09:16:22 (INFO ) [cxf-90722:public-interface:getClustersForSCP-12] Outbound Message
---------------------------
ID: 90722
Response-Code: 200
Encoding: UTF-8
Content-Type: application/soap+xml
Headers: {}
Payload: <?xml version="1.0" encoding="UTF-8"?>
<soap:Envelope>
  <soap:Body>
    <ns2:getClustersForSCPResponse>
      <return>
        <filteredResults>
          <id>0</id>
          <controllerIp>192.168.0.101</controllerIp>
          <name>cluster1</name>
          <totalAvailableSpaceInMB>222160</totalAvailableSpaceInMB>
          <uuid>46cd08d7-1e6d-11e4-904d-005056990685</uuid>
          <vserverReasons>Did not match protocol of NFS.</vserverReasons>
          <vserverReasons>Did not match profile Storage system platform type does not match profile platform type..</vserverReasons>
          <vservers>
            <id>10000151</id>
            <availableSpace>0</availableSpace>
            <controllerIp>192.168.0.101</controllerIp>
            <controllerUsername>admin</controllerUsername>
            <controllerUuid>e200c372-bb7e-11e4-a4b7-005056011d47</controllerUuid>
            <failedReason>NDMP Daemon needs to be configured in vServer Aware Mode, Did not match profile Storage system platform type does not match profile platform type..</failedReason>
            <fcpEnabled>false</fcpEnabled>
            <iscsiEnabled>true</iscsiEnabled>
            <name>svm1</name>
            <ndmpAllowed>false</ndmpAllowed>
            <nfs3Enabled>true</nfs3Enabled>
            <nfs41Enabled>false</nfs41Enabled>
            <nfsEnabled>true</nfsEnabled>
          </vservers>
        </filteredResults>
      </return>
    </ns2:getClustersForSCPResponse>
  </soap:Body>
</soap:Envelope>

 

 