In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

ONTAP Select LIFs don't failover when frontend Network is down

Views:
102
Visibility:
Public
Votes:
0
Category:
ontap-select
Specialty:
core
Last Updated:

Applies to

  • ONTAP Select
  • VMware ESXi

Answer

ONTAP only sees the virtualized HW which is presented to it by the ESXi hosts.

The Failover for the uplinks in Select is not provided by ONTAP itself, but it relies on the uplinks configured in the vswitch on VMware. Normally you have an active and passive links on the vswitch and they are connected to the physical NIC of the host.

If the physical links are down on the NIC of ESXi host but the uplinks are showing as up in VMware, ONTAP will not see it and LIFs don't failover.

This is expected behavior.