Skip to main content
NetApp Knowledge Base

Deploy API service is currently not available upon a VMotion

Views:
195
Visibility:
Public
Votes:
0
Category:
ontap-select-deploy-upgrade
Specialty:
ontapselect
Last Updated:

Applies to

  • ONTAP Select Deploy
  • VMware VMotion

Issue

  • Deploy UI is not available, when connecting via SSH the below error is seen:
Deploy API service is currently not available
  • Deploy Appliance was vmotioned recently.
  • Deploy syslog:

04:13:04 deploy kernel: [6715337.689708] vmw_balloon: failed to initialize vmci doorbell
04:13:25 deploy LogService.py[10371]: Closing Connection...
04:13:28 deploy systemd[1]: logging.service: Succeeded.
04:13:28 deploy systemd[1]: logging.service: Service RestartSec=100ms expired, scheduling restart.
04:13:28 deploy systemd[1]: logging.service: Scheduled restart job, restart counter is at 2.
04:13:28 deploy systemd[1]: sdotadmin_boot_phase4.service: Succeeded.
04:13:28 deploy systemd[1]: Stopped sdotadmin_boot_phase4.
04:13:28 deploy systemd[1]: Stopping sdotadmin_boot_phase4...
04:13:28 deploy systemd[1]: sdotadmin_boot_phase3.service: Succeeded.
04:13:28 deploy systemd[1]: Stopped sdotadmin_boot_phase3.
04:13:28 deploy systemd[1]: Stopping sdotadmin_boot_phase3...
04:13:28 deploy systemd[1]: Stopping ONTAP Select Deploy Server...
04:13:28 deploy systemd[1]: Stopping uWSGI...

  • ESXI Deploy VM VMware.log:

04:12:55.639Z| vmx| | I005: Received migrate 'from' request for mid id x, src ip.
04:12:55.640Z| vmx| | I005: MigrateSetInfo: state=8 srcIp=<srv_ip> dstIp=<dst_ip> mid=x uuid=y priority=low
04:12:55.640Z| vmx| | I005: MigrateSetState: Transitioning from state 0 to 8.
.
.
04:13:02.432Z| vcpu-0| | I005: Vix: [mainDispatch.c:4205]: VMAutomation_ReportPowerOpFinished: statevar=0, newAppState=1872, success=1 additionalError=0
04:13:02.432Z| vcpu-0| | I005: Vix: [mainDispatch.c:4122]: VMAutomationReportPowerStateChange: Reporting power state change (opcode=0, err=0).
04:13:02.432Z| vcpu-0| | I005: Vix: [mainDispatch.c:4122]: VMAutomationReportPowerStateChange: Reporting power state change (opcode=2, err=0).
04:13:02.432Z| vcpu-0| | I005: Transitioned vmx/execState/val to poweredOn
04:13:02.432Z| vcpu-0| | I005: Migrate: cleaning up migration state.
04:13:02.432Z| vcpu-0| | I005: MigrateSetState: Transitioning from state 12 to 0.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.