In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Can direct-attached storage (DAS) ONTAP Select and Deploy instances be Vmotioned when upgrading ESX firmware?

Views:
183
Visibility:
Public
Votes:
0
Category:
ontap-select
Specialty:
core
Last Updated:

Applies to

  • ONTAP Select
  • ONTAP Deploy
  • ESXi
  • VMware

Answer

DAS ONTAP Select HA nodes cannot be vmotioned.

  • Takeover/Givebacks will need to be completed during the ESXi firmware upgrade.

ONTAP Deploy can be Vmotioned prior to the upgrade.

  • It's recommended it be done cold by powering down the Deploy node, Vmotion, then power on. (This is non-disruptive to the HA cluster)

Additional Information

  • The upgraded ESX image must have the vendor RAID controller driver installed, so it will need to be downloaded from the ESX vendor. Do not use the vmware image.