Can direct-attached storage (DAS) ONTAP Select and Deploy instances be vMotioned when upgrading ESX firmware?

Views:
459
Visibility:
Public
Votes:
0
Category:
ontap-select
Specialty:
ontapselect
Last Updated:

Applies to

  • ONTAP Select
  • ONTAP Deploy
  • ESXi
  • VMware

Answer

DAS ONTAP Select HA nodes cannot be vmotioned.

  • Takeover/Givebacks will need to be completed during the ESXi firmware upgrade.

ONTAP Deploy can be Vmotioned prior to the upgrade.

  • It's recommended it be done cold by powering down the Deploy node, vMotion, then power on. (This is non-disruptive to the HA cluster)

Additional Information

  • The upgraded ESX image must have the vendor RAID controller driver installed, so it will need to be downloaded from the ESX vendor. Do not use the vmware image.
  • NetApp Interoperability Matrix can be used to verify the ONTAP Select/Deploy versions are supported with the new ESX image version.
  • ONTAP Select on VMware

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.