Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Unable to send network traffic over Cisco Nexus vPC with ip.fastpath enabled

Views:
481
Visibility:
Public
Votes:
0
Category:
data-ontap-7
Specialty:
7dot
Last Updated:

Applies to

ONTAP 7 and earlier

Issue

A performance impact or outage is experienced when accessing the storage system through the LAN after implementing Cisco's vPC on Nexus 7000 or 5500 series switches, when ip.fastpath is enabled.

The storage system will respond to the MAC address of an individual switch/router and not the virtual MAC address of the two vPC devices.

 

 

 