In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

ONTAP Panic: cg_nwk_my_ctx: Invalid CG ID 68 in process ifconfig

Views:
33
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

ONTAP 9.6 and earlier

Issue

Issue starts with

  1. node1 panics

cluster01-01: ifconfig: sk.panic:alert]: Panic String: cg_nwk_my_ctx: Invalid CG ID 68 in process ifconfig on release 9.5P11 (C)

 

  1. node2 takes over
  2. node2's  mgwd fails (while in take over)

cluster01-02: mgwd: ucore.panicString:error]: 'mgwd: Received SIGSEGV (Signal 11) at RIP 0x807a2b3d4 accessing address 0xffffffffffffffe8 (pid 2037, uid 0, timestamp 1609834297)'
 

  1. Then node2 panics with the same panic as node1 (while in takeover)

cluster01-02: ifconfig: sk.panic:alert]: Panic String: cg_nwk_my_ctx: Invalid CG ID 68 in process ifconfig on release 9.5P11 (C)

 

 