Which LIF of an SVM will be used for VSCAN?

Views:
848
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas
Last Updated:

Applies to

  • ONTAP 9
  • VSCAN
  • ONTAP AV Connector

Answer

  • AV Connector will issue an API call to the management LIF configured for polling to collect all CIFS enabled data LIFs on the SVM
  • From the LIFs returned it will attempt to connect to the SVM one-by-one in no particular order until a successful connection is established
  • ONTAP AV connector version 1.0.5P1 introduced a new feature that allows to configure data LIFs directly

Additional Information

The LIF used to poll on the AV Connector depends on the "Scanner Pool Config Owner" option set on scanner pool. 

  • If "Scanner Pool Config Owner" is defined as SVM , then you must configuree the ONTAP Antivirus Connector with the SVM management LIF or the SVM data LIF
  • If "Scanner Pool Config Owner" is defined as cluster, then you must have configured the ONTAP Antivirus Connector with the cluster management LIF

 