Skip to main content

NetApp_Insight_2020.png 

NetApp Knowledgebase

What does vticadapt_out_of_resources mean?

Views:
43
Visibility:
Public
Votes:
0
Category:
data-ontap-8
Specialty:
san
Last Updated:

 

Applies to

  • Data ONTAP operating in 7-Mode
  • SAN environment using FCP protocol
  • Can use any host operating system supported

Answer

  • The filer will display a message in the EMS log simiilar to this:
    • [Filer:scsitarget.info:info]: SCSI BUSY : vticadapt_out_of_resources
  • This message means the Virtual Target Interconnect (VTIC) on a FCP system is being overran with partner path traffic due to multipathing misconfiguration on the host side.
  • The resolution is to fix FCP initiator configuration to point to the correct filer. The article on FCP Partner Path Misconfigured has details on what this means and how to do this.

Additional Information

Add your text here.