  • NS224 drive shelf
  • ONTAP 9

Issue

When using NS224 drive shelf, SNMP Get value for OID enterprises.789.1.21.1.2.1.3.1 (enclChannelShelfAddr) is returned as 0x.<ShelfID>.
The name of the adapter is different from the port to which it is connected.

Example:

  • Result of "sysconfig" :

                e0c MAC Address:    00:a0:98:f6:ac:0c (auto-100g_cr4-fd-up)
                    QSFP Vendor:         Molex
                    QSFP Part Number:    112-00573
                    QSFP Serial Number:  93A1832020140
                    00.0.0: NETAPP   X4010S172B1T9NTE NQ60 1831.1GB 4160B/sect (S492NE0M100297)
                    00.0.1: NETAPP   X4010S172B1T9NTE NQ60 1831.1GB 4160B/sect (S492NE0M100285)
                    ....
                    00.0.23: NETAPP   X4010S172B1T9NTE NQ60 1831.1GB 4160B/sect (S492NE0M100224)
                    Shelf 0: NS224NSM100  Firmware rev. NSM100 A: E022  NSM100 B: E022

  • Result of "snmpget":

iso.3.6.1.4.1.789.1.21.1.2.1.3.1 = STRING: "0x.shelf0"        
iso.3.6.1.4.1.789.1.21.1.2.1.5.1 = STRING: "NS224NSM100"

 