In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

ONTAP controller disruption caused by time zone change

Views:
864
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

  • ONTAP 9.7
  • AFF and FAS Controllers

Issue

System disruptions occur with all versions of ONTAP 9.7 up to ONTAP 9.7P8 for storage systems in the IDT (Israel Daylight Savings Time) and NDT (Newfoundland Daylight Savings Time) time zones when they transition to standard time.
 

PANIC: process on cpu15 hung (cron_admin) for 5007 milliseconds! in SK process cron_admin on release 9.7P7 (C) 
on Sun Oct 25 01:00:05 IDT 2020.

 