Issue

The following errors can be seen in EMS:

Wed Mar 11 18:15:34 [vsim01@demo.netapp: OffloadWorker03: vscan.dropped.connection:warning]: CIFS: Virus scan server \\Vscanner (172.18.175.85) has disconnected from the filer.
Wed Mar 11 18:16:03 [vsim01@demo.netapp: SMBRPCWorker03: vscan.server.connecting.successful:info]: CIFS: Vscan server \\Vscanner registered with the filer successfully.
Wed Mar 11 18:28:21 [vsim01@demo.netapp: OffloadWorker01: vscan.dropped.connection:warning]: CIFS: Virus scan server \\Vscanner(172.18.175.85) has disconnected from the filer.
Mon Apr 11 18:31:34 [vsim01@demo.netapp:cifs.server.infoMsg:info]: CIFS: Warning for server \\Vscanner: Connection terminated.
Mon Apr 11 18:31:34 [vsim01@demo.netapp:cifs.server.errorMsg:error]: CIFS: Error for server \\Vscanner: Error while negotiating protocol with server STATUS_IO_TIMEOUT.

 