Skip to main content
NetApp Knowledge Base

LIF found on base port of its home ifgrp after a non-graceful shutdown in ONTAP 9

Views:
261
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
network
Last Updated:

Applies to

  • ONTAP 9

Issue

  • After a non-graceful shutdown (such as a power outage) and subsequent recovery, if a LIF was previously homed on single-port ifgrp, it may be found on the base port of its ifgrp.
    • In this event, you may find EMS errors such as:
 
[vifmgr_virtual_interface_iterator::move_imp] Well-known error thrown while moving LIF LIF_NAME (1000): Failed to update LIF "LIF_NAME" because port "CLUSTER-01:a0a" is in a different broadcast domain than the LIF's home port. Use the "network port broadcast-domain show" command to identify a port in the same broadcast domain as port "CLUSTER-01:e0c"
 
[kern_vifmgr:info:5526] [0x8089b2800] [FailoverMgr::scanIncorrigibleVifs] LIF LIF_NAME (1000) has no available failover targets on this node.
 
  • Upon running network interface show -lif LIF_NAME -instance, you may see the following status:
 
Operational Status: down
Extended Status: This LIF is down because all failover targets are either down or otherwise unavailable. Use the "network interface show -failover" command to review the LIF's failover configuration.
 
  • You may also be unable to ping to or from the LIF in this case, indicated no network connectivity from that interface.

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support