Answer

The threshold is hardcoded into the syslog message - the "80 percent" is not a variable and cannot be changed:

EMS Identifier wafl.vol.runningOutOfInodes
Severity ERROR
(…)  
Syslog Message The file system on %s %s%s%s is using 80 percent or more of the files that can be contained on the volume.
Parameters type (STRING): Type of object (volume or aggregate).
owner (STRING): Volume owner.
vol (STRING): Volume name.
volident (STRING): Unique volume identifier when the volume name alone is insufficient.
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.