In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

NetApp KCS Award

NetApp Knowledge Base

In what cases does "CONTROLLER TAKEOVER COMPLETE MANUAL" occur other than manual operation?

Views:
154
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

ONTAP 9

Answer

Due to the following EMS logs, no response from node B, and node A is initiated by schedule takeover, so Autosupport shows "CONTROLLER TAKEOVER COMPLETE MANUAL".

Example:
Mon Sep 28 16:31:58 +0900 [node_name: cf_main: cf.fsm.partnerNotResponding:notice]: Failover monitor: partner not responding
Mon Sep 28 16:31:58 +0900 [node_name: cf_main: cf.fsm.takeoverCountdown:info]: Failover monitor: takeover scheduled in 10 seconds