Skip to main content
NetApp Knowledge Base

HP Virtual connect module connected to host port going down repeatedly

Views:
820
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san
Last Updated:

Applies to

Ontap 9

The HP blade VC module is the connection between host and FC fabric/blade switching module.

Issue

  • Virtual connect module connected  to host port reported pause flooding and it responds by disabling the host connected port and therby losing the path to the storage.

Virtual connect logs:

2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENET PORT:enc0:iobay2:d5:3102:Major]  : Port was disabled because a pause flood was detected.
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENET PORT:enc0:iobay2:d5:v1:3102:Major]  : Port was disabled because a pause flood was detected.
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENET PORT:enc0:iobay2:d5:v2:3102:Major]  : Port was disabled because a pause flood was detected.
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENET PORT:enc0:iobay2:d5:v3:3102:Major]  : Port was disabled because a pause flood was detected.
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENET:enc0:iobay2:3020:Minor] Enet Module state DEGRADED : 1 or more ports LOOP_DETECTED or PAUSE_FLOOD_DETECTED, Previous: Enet Module state OK, Cause: Port enc0:iobay2:d5 pause-flood detected and automatically disabled
2021-03-07T02:52:57+01:00 VCEFX3C422301R4 vcmd: [ENC:enc0:2014:Minor] Enclosure state DEGRADED : Some Enet modules & servers not OK, Previous: Enclosure state OK, Cause: Port enc0:iobay2:d5 pause-flood detected and automatically disabled

 

  • Additionally, the host connected ports were acting as "slow drain" devices on the switch end.
  • The Buffer credit time outs were observed on some of the NPIV ports logged in to the switch.

MAPS data on switch end:
 
Category(Violation Count)|RepeatCount|Rule Name                  |Execution Time   |Object           |Triggered Value(Units)|
-----------------------------------------------------------------------------------------------------------------------------
Port Health(6)           |5          |ALL_F_PORTS_C3TXT0         |03/04/21 20:26:52|F-Port 11/17     |140 Timeouts          |
                         |           |                           |                 |F-Port 10/16     |156 Timeouts          |
                         |           |                           |                 |F-Port 10/16     |120 Timeouts          |
                         |           |                           |                 |F-Port 3/27      |217 Timeouts          |
                         |           |                           |                 |F-Port 10/16     |139 Timeouts          |

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.