Failure Error Message: Disk s cannot be used on a node configured as Flash Optimized
Applies to
- AFF platforms
- FAS platforms
- ONTAP
Issue
- EMS message is reported when adding hard disk drives to a FAS system:
Disk %s cannot be used on a node configured as Flash Optimized.
The disk should be removed from the system.
sysconfig -a
command reports the following output:
slot 0: SAS Host Adapter 0a (PMC-Sierra PM8001 rev. C, SAS, <UP>)
Firmware rev: 01.11.07.00
Base WWN: 5:00a098:0035310:20
Phy State: [0] Enabled, 6.0 Gb/s
[1] Enabled, 6.0 Gb/s
[2] Enabled, 6.0 Gb/s
[3] Enabled, 6.0 Gb/s
QSFP Vendor: Molex Inc.
QSFP Part Number: 112-00177+A0
QSFP Type: Passive Copper 2m ID:00
QSFP Serial Number: 132720554
00.8 : NETAPP X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
00.9 : NETAPP X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
01.0 : NETAPP X443_PLS15150A01 NQ10 142.8GB 520B/sect (66640)
01.1 : NETAPP X443_PLS15150A01 NQ10 142.8GB 520B/sect (66645)
Shelf 0: DS4246 Firmware rev. IOM6 A: 0173 IOM6 B: 0173
Shelf 1: DS4246 Firmware rev. IOM6 A: 0173 IOM6 B: 0173
storage disk show
command reports the following output:
Usable Disk Container Container
Disk Size Shelf Bay Type Type Name Owner
---------------- ---------- ----- --- ------- ----------- --------- --------
1.0.0 - 11 0 MSATA Unsupported - -
1.0.1 - 11 0 MSATA Unsupported - -
1.0.2 - 11 0 MSATA Unsupported - -
1.0.3 - 11 0 MSATA Unsupported - -
1.0.4 - 11 0 MSATA Unsupported - -
1.0.5 - 11 0 MSATA Unsupported - -
storage disk error show
command reports the following output:
Disk Error Type Error Text
---------------- ----------------- --------------------------------------------
2.3.0 persona-mismatch The node is configured with flash optimized personality and this disk is not SSD. The Disk needs to be removed.
2.3.1 persona-mismatch The node is configured with flash optimized personality and this disk is not SSD. The Disk needs to be removed.