Issue

  • EMS message is reported when adding hard disk drives to a FAS system:

Disk %s cannot be used on a node configured as Flash Optimized.
The disk should be removed from the system.

  • sysconfig -a command reports the following output:

slot 0: SAS Host Adapter 0a (PMC-Sierra PM8001 rev. C, SAS, <UP>)
Firmware rev: 01.11.07.00
Base WWN: 5:00a098:0035310:20
Phy State: [0] Enabled, 6.0 Gb/s
[1] Enabled, 6.0 Gb/s
[2] Enabled, 6.0 Gb/s
[3] Enabled, 6.0 Gb/s
QSFP Vendor: Molex Inc.
QSFP Part Number: 112-00177+A0
QSFP Type: Passive Copper 2m ID:00
QSFP Serial Number: 132720554
00.8 : NETAPP X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
00.9 : NETAPP X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
01.0 : NETAPP X443_PLS15150A01 NQ10 142.8GB 520B/sect (66640)
01.1 : NETAPP X443_PLS15150A01 NQ10 142.8GB 520B/sect (66645)
Shelf 0: DS4246 Firmware rev. IOM6 A: 0173 IOM6 B: 0173
Shelf 1: DS4246 Firmware rev. IOM6 A: 0173 IOM6 B: 0173

 

  • storage disk show command reports the following output:

Usable                 Disk           Container   Container
Disk                   Size Shelf Bay Type       Type        Name      Owner
---------------- ---------- ----- --- -------    ----------- --------- --------
1.0.0                     -    11   0 MSATA      Unsupported -         -
1.0.1                     -    11   0 MSATA      Unsupported -         -
1.0.2                     -    11   0 MSATA      Unsupported -         -
1.0.3                     -    11   0 MSATA      Unsupported -         -
1.0.4                     -    11   0 MSATA      Unsupported -         -
1.0.5                     -    11   0 MSATA      Unsupported -         -

  • storage disk error show command reports the following output:

Disk             Error Type        Error Text
---------------- ----------------- --------------------------------------------
2.3.0            persona-mismatch  The node is configured with flash optimized personality and this disk is not SSD. The Disk needs to be removed.
2.3.1            persona-mismatch  The node is configured with flash optimized personality and this disk is not SSD. The Disk needs to be removed.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.