Skip to main content
NetApp Knowledge Base

Enabling deduplication fails with Operation is not configured error following 7MTT migration

Views:
676
Visibility:
Public
Votes:
0
Category:
data-ontap-8
Specialty:
core
Last Updated:

Applies to

  • Clustered Data ONTAP 8.2.x
  • Data migrated using 7-Mode Transition Tool (7MTT) 
  • ONTAP 9

Issue

  • Enabling volume efficiency or running any volume efficiency operation fails with an Operation is not configured error:

cluster01::> volume efficiency on -vserver svm1 -volume vol1
Error: command failed: Failed to enable efficiency on volume "vol1" of Vserver "svm1": Operation
       is not configured.

  • Onlining or offlining the volume does not resolve the issue:

cluster01::> volume offline -volume vol1 -vserver svm1

Volume "svm1:vol1" is now offline.
 
cluster01::> volume online  -volume vol1 -vserver svm1

Volume "svm1:vol1" is now online.
 

cluster01::> volume efficiency on -vserver svm1 -volume vol1
Error: command failed: Failed to enable efficiency on volume "vol1" of Vserver "svm1": Operation
       is not configured.

  • This issue may also been seen during a volume move operations.  The volume move hangs at 98% and reports a Deduplication operation is not configured error.

 

 