Convert volume to FlexGroup failed due to Volume config database read failed (entry doesn't exist)
Applies to
- ONTAP 9.x
- FlexGroup
Issue
During converting a volume to FlexGroup, reports error:
::>volume conversion start -volume TEST -check-only true
Error: command failed: Cannot convert volume "TEST" in Vserver "NetApp" to a FlexGroup because one or more errors occured checking the volume. Reasons:
* Conversion failed with reason Volume config database read failed (entry doesn't exist).
In vol converson validation show
shows volume-snapmirror-dstconvert-check
error:
::*>volume conversion validation show -volume TEST -vserver NetApp
Vserver : NetApp
Volume : TEST
Precheck Status
------------------------------------------------ ------------
volume-snapmirror-nosnap supported
volume-snapmirror-bre supported
volume-snapmirror-storage-efficiency supported
volume-snapmirror-fvSource supported
volume-snapmirror-LTR supported
volume-snapmirror-VserverDR supported
volume-snapmirror supported
volume-snapmirror-broken supported
volume-snapmirror-fanout supported
volume-snapmirror-dstconvert-check error
Reason : Conversion failed with reason Volume config database read failed
(entry doesn't exist)
volume-reallocation-schedule supported
volume-nvme-namespace supported
volume-statistics supported
volume-space-slo supported
volume-snapmirror-sync supported
application-volume supported
volume-v4-inode supported
...