Skip to main content
NetApp Knowledge Base

Can I use a wildcard to disable vol efficiencies on SVM-DR destination vol in ONTAP?

Views:
101
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

  • ONTAP 9.9.1

Answer

In ONTAP 9.9.1 the override -command will fail with the following error:

::> set diag

::*> vserverconfig override -command "volume efficiency off -vserver de*ts* -volume sou*"

Error: command failed on vserver "destsvm" volume "source1": This operation is not permitted on a Vserver that is configured as the destination for identity preserve Vserver DR.

Additional Information

Previous ONTAP versions do allow the use of wildcards.
 
ONTAP 9.7:
::*> vserver config override -command "volume efficiency off -vserver des*tsvm* -volume sou*"
Efficiency for volume "source1" of Vserver "destsvm" is disabled.
Efficiency for volume "source2" of Vserver "destsvm" is disabled.
Efficiency for volume "source3" of Vserver "destsvm" is disabled.
3 entries were acted on.
  • Our Development Team is currently in the process of comparing code between 9.9.1 and 9.7

Please contact NetApp Technical Support or log into the NetApp Support Site to create a case. Reference this article for further assistance.

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.