In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

NetApp KCS Award

NetApp Knowledge Base

CRC errors seen after upgrading to ONTAP 9.7P5

Views:
1,558
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
network
Last Updated:

Applies to

  • ONTAP 9.7P5
  • CRC Errors

Issue

Following errors are observed in EMS:

Fri Jun 26 01:10:33 [nodeA: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0c on node nodeA is reporting a high number of observed hardware errors, possibly CRC errors.

Frame discards for transmit are increasing due to Queue overflow on the onboard Gigabit Ethernet NIC port :

::> system node run -node <node_name> -command ifstat -a 

TRANSMIT
Total frames:    97068k | Frames/second:     562  | Total bytes:       146g
Bytes/second:      847k | Total errors:        0  | Errors/minute:       0
Total discards:    432k | Queue overflow:    432k | Multi/broadcast:  5776 

 

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support