In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

CLUSTER NETWORK DEGRADED messages after controller upgrade

Views:
44
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

  • ONTAP 9.7P6
  • Controller upgrade
  • Temporary Cluster LIF

Issue

  • Following a controller upgrade, the cluster sends CLUSTER NETWORK DEGRADED alerts with no apparent reason
  • EMS reports ping failure between two Cluster LIFs

Mon Dec 20 04:50:47 +0100 [node02: vifmgr: callhome.clus.net.degraded:alert]: Call home for CLUSTER NETWORK DEGRADED: Total Packet Loss - Ping failures detected between node02_clus1 ( 169.254.2.92 ) on node02 and node01_test ( 169.254.111.226 ) on node01

  • LIF node01_test does not show in the output of network interface show
  • The missing LIF was created to allow controller upgrade to complete and has since been deleted