Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Bringing down single cluster port manually on one node for test purpose leads to service outage

Views:
37
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

  • ONTAP 9
  • Two-Node Switchless Cluster (TNSC)
  • Intel 10/40 Gigabit Ethernet Controller XL710 QSFP+

Issue

  • When making single cluster port down manually on one node by the following command, the corresponding directly wired cluster port on the other node isn't down automatically.

network port modify -node <node name> -port <one of cluster ports> -up-admin false

  • This will cause vifmgr flapping and hence data LIFs don't function.

 