In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.

NetApp KCS Award

NetApp Knowledge Base

ANDU paused on error due to timeout releasing disk reservations

Views:
108
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
metrocluster
Last Updated:

Applies to

  • ONTAP 9.7
  • ONTAP 9.8
  • MCC-IP
  • AFF-A320

Issue

  • During an ANDU of a Metrocluster-IP from ONTAP 9.7P3 to ONTAP 9.8P7 the cluster image update process paused on error after the takeover and reboot of the first node in each cluster.
  • After the node was taken over and rebooted it came to a point where it kept spamming the console with the message: Waiting for reservations to clear
  • When we booted the node to maintenance mode we found that the ha-config values for the controller and chassis had been set to "ha" instead of the required value "mccip" for this configuration.